Precautions warm installation

1 , equipped with warm indoor display furniture , should be kept away from the floor space of more than 5cm place objects to the proliferation of geothermal upward.
2 , when warm interiors , non strongly hits the ground or the floor drilling , nailing , cutting, boreholes , etc., to prevent damage to the heating pipe .
3 , in the heating region , especially heavy items should not be placed on the ground , to prevent cracking of ground deformation , it is necessary reinforcement measures should be taken on the ground wpc outdoor decking.
4 , high-temperature operation is prohibited on the ground . If a fire or electric furnace , etc., to prevent damage to underground plastic pipe.
5 , uninhabited room in winter , the temperature in the following 0 ℃, should use the pump to warm the water inside the tube all out , it is best not to do a drop left , to prevent pipe cracking.
6 , do not advocate additional wood floor under the keel , that would reduce the cooling effect , but also easily nail nails keel damage pipes. Should maximize the use of the adhesive type, fight pluggable composite plate made ​​of artificial wood floor better.
7 , when a user if drilling between floors , the roof , be sure to pay attention to the structure of the drilling depth can not exceed the thickness of the floor to prevent damage to the upper floor heating pipes and insulation composite wood porch floor.
8 , if the floor heating pipes piping leaks occur once , be sure to turn off the head of the valve manifold manifold , and then notify the installation unit for repair.
9 , the heating pipe is strictly prohibited and asphalt, gasoline, alcohol exposure , to prevent against corrosion of pipes.
10 , in each heating period, before using the warm , open water separator filter on the water supply pipes to remove debris . Specific methods : First close the inlet , backwater valve connecting the heating pipes , and then open the filter , remove and clean the filter network , check the filter network for damage , blockage , if damaged should be replaced with the specifications of the filter network , as is installed . In the crack installation process , do not allow debris to enter the tube . Dealt with, and then filter on tight to prevent leakage. After the system is running , do not arbitrarily adjust the valve on the manifold Composite Fencing Materials.

Keywords: exterior flooring options cape town garden furniture polywood architectural exterior cladding wood composite composite garden screening veranda composite fence panels distributors modular decks for swimming pools decking producers in china cheap 3 foot high fence panels sipscomposite panel roof deck wooden gazebo kits for on decks wooden plant pot making kits what are the advantages of panel doors how to cover grooves in decking paneling veranda wpc wood railings modular plastic decking.